PM-CARE SPECULUM

CUSCO OR COLLIN SPECULUM



The PM-CARE® SPECULUM speculum is used to explore, view, and examine the uterine cervix and vagina, and to access the cervical canal and uterine cavity when performing various examinations and surgical procedures. The Collin speculum enables larger devices to be inserted. The PM-CARE® SPECULUM is made from very high quality medical thermoplastic material.

AVAILABLE REFERENCE(S)

Reference

Model

Size

Diameter

(mm)

Colour

Reference

PS3592000

Model

Cusco

Size

XS

Diameter

(mm)

20

Colour

White

Reference

PS3592400

Model

Cusco

Size

S

Diameter

(mm)

24

Colour

Blue

Reference

PS3592600

Model

Cusco

Size

M

Diameter

(mm)

26

Colour

Red

Reference

PS3593000

Model

Cusco

Size

L

Diameter

(mm)

30

Colour

Green

Reference

PS3932700

Model

Collin

Size

S

Diameter

(mm)

27

Colour

White

Reference

PS3933000

Model

Collin

Size

M

Diameter

(mm)

33

Colour

Green

ABOUT THIS MEDICAL DEVICE

1st release date

Speculum Cusco : 2012

Speculum Collin : 2015

Single use

Yes

Classe

Is

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

• Cusco Speculum: box of 50 units in individual sterile wrapping

• Collin Speculum: box of 35 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE HYSTEROMETRE

HYSTEROMETER



The PM-CARE® HYSTEROMETRE hysterometer is used to assess uterine depth during gynaecological examinations, in particular for the insertion or removal of a contraceptive device.

AVAILABLE REFERENCE(S)

Reference

Diameter

(Fr)

Diameter

(mm)

Colour

Reference

PS1251000

Diameter

(Fr)

10

Diameter

(mm)

3,3

Colour

Blue

Reference

PS1251200

Diameter

(Fr)

12

Diameter

(mm)

4

Colour

Grey

Reference

PS1251400

Diameter

(Fr)

14

Diameter

(mm)

4,6

Colour

Green

ABOUT THIS MEDICAL DEVICE

1st release date

2002

Single use

Yes

Classe

Is

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 25 or 10 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE ENDOBIOPS

HISTOLOGICAL SAMPLING CATHETERE



The PM-CARE® ENDOBIOPS histological sampling catheter is used to take histological samples from the endometrium.

ADVANTAGES

• Centimetric graduations for better control of catheter insertion.

• Atraumatic tip enabling smooth introduction into the cervical canal.

• Rigid and notched grip tip for a firm grip.

• Efficient aspiration provided by negative pressure.

AVAILABLE REFERENCE(S)

Reference

Model

Diameter

(mm / Fr)

Length

(cm)

Reference

PS1200923

Model

STANDARD

Diameter

(mm / Fr)

3 / 9

Length

(cm)

23

Reference

PS1210626

Model

MINI

Diameter

(mm / Fr)

2 / 6

Length

(cm)

27

ABOUT THIS MEDICAL DEVICE

1st release date

2002

Single use

Yes

Classe

Is

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 25 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-LIFE IU

INSEMINATION CATHETERE



The PM-LIFE® IU intrauterine insemination catheter is used to perform insemination during medically

assisted reproduction (MAR), by introducing washed and prepared sperm into the uterine cavity. Some

product references feature an inserter, to stabilise and guide the catheter during insertion, and/or a mandrel to pre-shape the distal end of the catheter in order to adapt to the patient’s morphology.

ADVANTAGES

• Centimetric graduations for better control of catheter insertion.

AVAILABLE REFERENCE(S)

Référence

Diameter

for catheter

(mm / Fr)

Inner

diameter

volume

(mm / ml)

2 lateral

holes

diameter

(mm)

Useful

length

Length

of the distal

part

(mm)

Insertor

Mandrel

Référence

PS1260500

Diameter

for catheter

(mm / Fr)

1,6 / 5

Inner

diameter

volume

(mm / ml)

1,1 / 0,20

2 lateral

holes

diameter

(mm)

1

Useful

length

175

Length

of the distal

part

(mm)

45

Insertor

-

Mandrel

-

ABOUT THIS MEDICAL DEVICE

1st release date

2002

Single use

Yes

Classe

Is

Sterile

Yes

Sterilisation method

Sterilised via gamma radiation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 25 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-LIFE FIV IU

EMBRYO TRANSFER CATHETER



The PM-LIFE® FIV IU embryo transfer catheter is used for intrauterine insemination or to perform a microinjection (transfer of embryos after in vitro fertilisation). Some product references come with an opaque tube for better ultrasound visualisation, or a mandrel to adapt the catheter to the patient's morphology.

ADVANTAGES

• Centimetric graduations and stopper for better control of catheter insertion.

AVAILABLE REFERENCE(S)

Reference

Catheter

diameter

(mm / Fr)

Inner diameter

/ volume

(mm / ml)

Excess

of the supple catheter

(mm)

Useful

length

(mm)

Tube

opaque

Mandrin

Mandrel

Reference

PS1280545

Catheter

diameter

(mm / Fr)

1,6 / 5

Inner diameter

/ volume

(mm / ml)

1,1 / 0,20

Excess

of the supple catheter

(mm)

45

Useful

length

(mm)

175

Tube

opaque

-

Mandrin

Mandrel

-

Reference

PS2380545

Catheter

diameter

(mm / Fr)

1,6 / 5

Inner diameter

/ volume

(mm / ml)

1,1 / 0,20

Excess

of the supple catheter

(mm)

45

Useful

length

(mm)

175

Tube

opaque

-

Mandrin

Mandrel

Yes

INFORMATIONS SUR LE DISPOSITIF MÉDICAL

1st release date

2002

Single use

Yes

Classe

Is

Sterile

Yes

Sterilisation method

Sterilised via gamma radiation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 25 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE 1V-STD

1-LUMEN RIGID HYSTEROGRAPHY AND HYSTEROSONOGRAPHY CATHETER WITH FOAME



The PM-CARE® 1V-STD 1-lumen rigid hystero catheter with foam is used to perform hysterography and

hysterosonography and to ensure a tight seal during the examination. The sliding catheter also enables a deeper penetration into the uterine cavity for injection.

ADVANTAGES

• Easy and simple manipulation.

• Sealing ensured by positioning the foam against the cervix.

• Ease of product injection.

• Atraumatic insertion.

AVAILABLE REFERENCE(S)

Reference

Catheter diameter

(mm / Fr)

Foam diameter

(mm)

Catheter length

(mm)

Sliding

catheter

Reference

PS1870733

Catheter diameter

(mm / Fr)

2,45 / 7,5

Foam diameter

(mm)

15

Catheter length

(mm)

330

Sliding

catheter

-

Reference

PS2010733

Catheter diameter

(mm / Fr)

2,45 / 7,5

Foam diameter

(mm)

25

Catheter length

(mm)

330

Sliding

catheter

-

Reference

PS2020733

Catheter diameter

(mm / Fr)

1,5 / 4,5

Foam diameter

(mm)

15

Catheter length

(mm)

340

Sliding

catheter

yes

ABOUT THIS MEDICAL DEVICE

1st release date

2004,2005 pour la référence PS2020733

Single use

Yes

Classe

Is

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 5 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE FORBIOPS

BIOPSY FORCEPSE

The PM-CARE® FORBIOPS biopsy forceps is used to perform biopsies on suspect areas of the

cervix.

ADVANTAGES

• Scissor-shaped handle for easy manipulation.

• Easy sampling with the jaws of the forceps.

• Detachable pusher for easy retrieval of the sampling.

AVAILABLE REFERENCE(S)

Reference

Length

(cm)

Reference

PS3600025

Length

(cm)

26

ABOUT THIS MEDICAL DEVICE

1st release date

2013

Single use

Yes

Classe

IIa

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 20 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE CHERON

CHERON FORCEPSE



PM-CARE® CHERON Cheron forceps are used to insert or remove an intrauterine device during

gynaecological examinations or procedures. During consultations or gynaecological care, it can be used

to grip an aseptic dressing, tampon or compress to apply disinfectant and/or clean the cervix or work

area.

PM-CARE® CHERON Cheron forceps can be straight or angled to adapt to the shape of the uterus. The

practitioner can choose to use straight or angled forceps according to their personal preferences and

ease in the act to be performed.

AVAILABLE REFERENCE(S)

Reference

Forceps model

Reference

PS3200025

Forceps model

Straight

Reference

PS3210025

Forceps model

Angled

ABOUT THIS MEDICAL DEVICE

1st release date

2011

Single use

Yes

Classe

ls

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 20 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE INSERT-KIT

IUD INSERTION KITE



The PM-CARE® INSERT-KIT IUD insertion kit is used to insert an intrauterine device in the intrauterine

cavity. It is composed of a Pozzi forceps, a Cheron forceps, a pair of string scissors and a hysterometer.

IUD INSERTION KIT COMPONENTS:

• The straight Pozzi forceps grasps the cervix, performing “traction-fixation” on the cervix to enable the

flexion angle of the uterus to be adjusted to 180°. This correction of the flexion angle is necessary in

order to insert instruments and fit the intrauterine device without risking uterine perforation.

• The angled Cheron forceps cleans the uterus and the working area.

• Lateral or distal string scissors are used to cut the strings of the intrauterine device.

The practitioner can choose to use a pair of lateral or distal string scissors according to their personal

preference and ease in the act to be performed.

• The hysterometer is used to assess the depth of the uterine cavity.

RÉFÉRENCE(S) DISPONIBLE(S)

Reference

PINCE DE

POZZI

Model

PINCE DE CHÉRON

Model

CISEAUX

COUPE-FIL

Model

HYSTÉROMÈTRE

Diameter

(Fr)

Reference

PS3230000

PINCE DE

POZZI

Model

Straight

PINCE DE CHÉRON

Model

Angled

CISEAUX

COUPE-FIL

Model

Lateral

HYSTÉROMÈTRE

Diameter

(Fr)

14

Reference

PS3840000

PINCE DE

POZZI

Model

Straight

PINCE DE CHÉRON

Model

Angled

CISEAUX

COUPE-FIL

Model

Distal

HYSTÉROMÈTRE

Diameter

(Fr)

14

INFORMATIONS SUR LE DISPOSITIF MÉDICAL

1st release date

2011

Single use

Yes

Classe

ls

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 10 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE REMOV-KIT

SET DE RETRAIT DE STÉRILET



Le set de retrait de stérilet PM-CARE® REMOV-KIT permet l‘extraction d’un dispositif intra-utérin de

la cavité utérine. Il est composé d’une pince de Pozzi, d’une pince d’extraction, d’une paire de ciseaux

coupe-fil et d’un hystéromètre.

COMPOSITION DU SET DE RETRAIT DE STÉRILET :

• La pince de Pozzi droite permet la préhension du col utérin et la réalisation d’une “traction-fixation” sur

le col utérin afin de permettre d’ajuster l’angle de flexion de l’utérus à 180°. Cette correction de l’angle

de flexion est nécessaire lors du retrait du dispositif intra-utérin sans prendre le risque de perforer

l’utérus.

• La pince d’extraction de stérilet permet de retirer en douceur et de nettoyer l’utérus et la zone

de travail.

• Les ciseaux coupe-fil distal permettent de couper les fils du dispositif intra-utérin.

• L’hystéromètre permet d’apprécier la profondeur de la cavité utérine.

RÉFÉRENCE(S) DISPONIBLE(S)

Référence

PINCE DE

POZZI

Modèle

PINCE

D’EXTRACTION

Fournie

CISEAUX

COUPE-FIL

Modèle

HYSTÉROMÈTRE

Diamètre

(Fr)

Référence

PS3620000

PINCE DE

POZZI

Modèle

Droite

PINCE

D’EXTRACTION

Fournie

Oui

CISEAUX

COUPE-FIL

Modèle

Distal

HYSTÉROMÈTRE

Diamètre

(Fr)

14

INFORMATIONS SUR LE DISPOSITIF MÉDICAL

1st release date

2011

Single use

Yes

Classe

ls

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 10 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE REMOV

IUD REMOVAL FORCEPS



The PM-CARE® REMOV IUD removal forceps are used during a gynaecological examination

• When removing an intrauterine device. It holds the strings of the device to pull it down for removal.

• When inserting a new device. It makes it possible to hold a compress for disinfecting and cleaning the

work area and/or the cervix soiled by the removal and to prepare the insertion of the new device.

AVAILABLE REFERENCE(S)

Reference

Length

(cm)

Reference

PS3570025

Length

(cm)

25

ABOUT THIS MEDICAL DEVICE

1st release date

2011

Single use

Yes

Classe

ls

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 20 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE EASYCUT

CISEAUX COUPE- FIL



The PM-CARE® EASYCUT string scissors are used for cutting strings when inserting an intrauterine

device. The practitioner can choose to use a pair of lateral or distal string scissors according to their

personal preference and ease in the act to be performed.

AVAILABLE REFERENCE(S)

Référence

Modèle

Référence

PS3220022

Modèle

LATERAL

Référence

PS3580022

Modèle

DISTAL

INFORMATIONS SUR LE DISPOSITIF MÉDICAL

1st release date

2011

Single use

Yes

Classe

ls

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 20 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

PM-CARE 3V-BALLOON

3-LUMENS MALLEABLE HYSTEROGRAPHY AND HYSTEROSONOGRAPHY CATHETER WITH BALLOONE



The PM-CARE® 3V-BALLOON 3-lumens malleable hystero catheter with balloon is used to perform

hysterography and hysterosonography. This malleable catheter can be bent and shaped to adapt to the patient's anatomy.

ADVANTAGES

• Easy and simple manipulation.

• Sealing guaranteed by the silicone balloon.

• Standard connector for connecting a syringe for product injection.

• Atraumatic insertion.

AVAILABLE REFERENCE(S)

Reference

Catheter diameter

(mm / Fr)

Inflated Balloon

diameter

(mm)

Balloon insufflation

max gas

(cc)

Length

(mm)


Reference

PS3310733

Catheter diameter

(mm / Fr)

2,66 / 8

Inflated Balloon

diameter

(mm)

13

Balloon insufflation

max gas

(cc)

2,5

Length

(mm)


230

ABOUT THIS MEDICAL DEVICE

1st release date

2011

Single use

Yes

Classe

Is

Sterile

Yes

Sterilisation method

Ethylene oxide sterilisation

Contains latex

No

Lifetime

5 years

Certification

CE

Packaging

Box of 5 units in individual sterile wrapping

Storage

In its original box in a cool and dry place

⏫ Go To Top ⏫